- Flow rates designed on temperatures of 25°C or 77°F
- Steel epoxy painted frame is standard (stainless steel frame is optional)
- 1” NPT Burkert Inlet Solenoid Valve
- 1” NPT high pressure prefilter housing c/w pressure release 500 PSI burst pressure, 125 PSI maximum operating pressure, 20” long
- 4 1/2” x 20” 5 micron polypropylene prefilter replacement cartridge
- stainless steel high pressure booster pump c/w TEFC motor
- Low pressure pretreatment plumbed in PUC pipe and fittings
- High pressure tubing with stainless steel fittings from booster pump through membrane system
- Flow meters measuring product water, recirculation and waste
- Stainless steel oil filled pressure manual control valve to increase and decrease pump pressure waste water and recirculation for up to 80 percent waste water reduction controlled by recirculation flow meter
- Low pressure feed water pressure switch
- High pressure feed water pressure switch
- Stainless steel membrane housings with end caps
- 4” by 40” low energy high quality thin film composite reverse osmosis membranes
- MICROPROCESSOR CONTROLLER STANDARD FEATURES:
- Multifunction key pad
- Display backlit LCD (4 lines / 20 character)
- Visual and Audible alarms
- Monitoring via PC
- Programmable time delays and setpoints
- All readings are field programmable for metric and US valves
- Write protected setpoints
- High/low pressure automotive reset alarm silence
- Non metallic Nema 4x enclosure
- 12” x 10” x 6” (305mm x 254mm x 152mm)
- Panel mount
|