- 1” NPT inlet and outlet top mounted composite electronic control valve.
- Electronic flow meter with accuracy within plus or minus 5 percent, flow rate range
0.25 to 27 gpm. Gallons range 20 to 50,000 gallons, 1000 to 9,999,000, totalizer.
- Service flow rate up to 27 gpm, peak flow rate up to 32 gpm, backwash flow rates
up to 27 gpm.
- Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill and service.
- Parallel flow, alternating on demand soft water.
- Cycles of operation. Cycle One backwash 6-12 minutes, Cycle Two
draw/slow rinse 45-75 minutes, Cycle Three second backwash 3-12 minutes, Cycle Four fast rinse 3-8 minutes, Cycle Five regeneranat refill (in service
with treated water), Cycle Six service.
- Four methods to initiate regeneration, meter immediate, meter delayed, time
clock delayed or pressure differential.
- 1” water distribution system utilizing single point distributor or hub and laterals
for maximum flowrates.
- Operating pressure 20-125 psi / 138-861 kpa, operating temperature
40°F - 110°F (5°C - 44°C).
- Solid state microprocessor c/w display for time of day, days until next regeneration,
volume remaining, current flow rate and total volume used (totalizer).
- Double backwash for optimum regeneration cleaning ability and salt efficiency.
- 12 volt output AC transformer.
- 1 – 28 day override on control valve programming.
- Brine tank salt grid for easy cleaning.
- Brine tanks 18” x 33” or 24" x 50" c./w brine well and safety float to eliminate overflowing tanks.
The brine tank has 500lb or 800lb water softening salt capacity.
- 1” FPT drain line, 1⁄2” FPT brine line.
|