- 1” NPT inlet and outlet top mounted composite electronic control valve.
- Electronic flow meter with accuracy within plus or minus 5 percent,
flow rate range 0.25 to 27 gpm.
Gallons range 500 to 250,000,
totalizer 1 to 9,999,000 gallons.
- Service flow rate up to 27 gpm, peak flow rate up
to32 gpm, backwash flow rates up to 27 gpm.
- Fully adjustable 6 cycle controls backwash,
slow/fast rinse, draw, refill and service.
- Treated water on demand.
- Cycles of operation. Cycle One backwash 6-12
minutes, Cycle Two draw/slow rinse 45-75
minutes, Cycle Three second backwash 3-12
minutes, Cycle Four fast rinse 3-8 minutes, Cycle Five regeneranat refill (in service with
treated water),
Cycle Six service.
- Four methods to initiate regeneration, meter
immediate, meter delayed, time clock delayed or
pressure differential.
- 1” water distribution system utilizing single point
distributor or hub and laterals for maximum flowrates.
- Operating pressure 20-125 psi / 138-861 kpa, operating
temperature 40°F - 110°F (5°C - 44°C).
- Solid state microprocessor c/w display for time of day,
days until next regeneration, volume remaining, current
flow rate and total volume used (totalizer).
- Double backwash for optimum regeneration cleaning ability
and salt efficiency.
- 12 volt output AC transformer.
- 1 – 28 day override on control valve programming.
- Brine tank salt grid for easy cleaning.
- Brine tanks 18” x 33” or 24”x 50” c./w brine well and safety
float to eliminate overflowing tanks.
The brine tank has 500lb
or 800lb water softening salt capacity.
- 1” FPT drain line, 1/2” FPT brine line.
- Caustic Soda Injection System.
|